Grundfos UP10-16BN5/ATLC Comfort Series 1/33 HP Recirculator Pump with Threaded Connection includes timer, aquastat, and line cord. The Grundfos circulator pumps, Series UP, are specifically designed for heating systems. The pumps are also suitable for circulation of hot domestic water and for circulation of liquid in cooling and air-conditioning systems.
Flow range: 0 - 3 U.S. GPM
Head range: 0 - 5.5 FEET
Motors: Single Phase, 115V
Maximum fluid temperature: 203°F (95°C)
Minimum fluid temperature: 36°F (2°C)
Maximum working pressure: 145 PSI
Electrical Connection: The pump is fitted with 5 foot cord and 115V plug
Motor Protection: Impedance-protected. No external motor protection required
Connection: 1/2" Copper Pipe, Female sweat fittings
ATLC = Aquastat, Timer, Line Cord
Domestic hot water recirculation systems in single and two-family houses
Small heating systems
Domestic hot water
Non-potable water
Softened water
|